Detector | Photomultiplier tubes (PMT) and/or photodiode |
2 PMT | Photo-multiplier tube | 2 PMT | 1, or 2 Ultra-fast Photomultiplier Tubes |
Silicon Photodiode + PMT |
Spectral range | 300-850 nm | 300-850 nm | 250-850 nm | 250-850 nm | 380-630 nm | F3: 400 – 650nm FilterMax F5: 400 – 750 nm |
Dynamic range | > 6 decades | > 6 decades | > 6 decades | > 6 decades | > 9 decades | > 6 decades |
Sensitivity | 3 pM for 96-wells, 6 pM for 384-wells (Optimized for ATP-Glow) |
1.25 pM for 96-wells, 3 pM for 384-wells, 19 pM for 1536-wells (Optimized for ATP-Glow) |
43 pM ATP in 96 wells (optimized) |
< 2 fg/well for firefly luciferase in 96- and 384-well top read | < 20 attomol ATP per well | |
Microplate format | 6 to 1536 wells* | 6 to 1536 wells | 6-384-well microplates | 6-384 (96- and 384-wells with pipetting) |
96- and 384-well microplates | F3: 96 – 384 well F5: 6 – 1536 well |
Cross-talk | < 0.4% in white 96- and 384-well microplates | < 0.3% in white 96- and 384-well microplates | < 0.3% in white 96- and 384-well microplates | < 3 x 10-5 (96-well) | ||
Read modes | Spectral, Endpoint, Kinetic | Endpoint, Kinetic | Endpoint, Kinetic | Endpoint, Kinetic, Fast Kinetic | Endpoint, Kinetic, Fast Kinetic, Dual-read |
Endpoint, Kinetic, Linear Scan, Area Scan |
Read times | 0:30 minutes for 96-wells, 1:15 minutes for 384-wells |
2:00 minutes for 96-wells, 7:00 minutes for 384-wells |
2:00 minutes for 96-wells, 7:00 minutes for 384-wells |
0.1 up to 3600 sec. in steps of 0.1 sec. |
18sec/96well 37sec/384well |
|
Injectors/pipettors | Option available | 8- or 16-channel pipettor | 2 variable volume injectors | |||
Injection/pipettor volumes | Max. volume 200uL for 8-channel and 30 uL for 16-channel |
|||||
Temperature control | 2 degrees C above ambient to 45 degrees C |
2 degrees C above ambient to 45 degrees C |
2 degrees C above ambient to 45 degrees C |
2 degrees C above ambient to 45 degrees C |
5 degrees C above ambient to 45 degrees C |
|
Software | SoftMax Pro Software | SoftMax Pro Software | SoftMax Pro Software | SoftMax Pro Software | SoftMax Pro Software | SoftMax Pro Software |
Validation & compliance tools | IQ/OQ Protocols, SoftMax Pro GxP Compliance Software, SpectraTest LM1 Validation Plate |
SoftMax Pro GxP Compliance Software |
IQ/OQ Protocols, FDA 21 CFR Part 11 Compliance, SpectraTest LM1 Validation Plate |
IQ/OQ/PQ Protocols, FDA 21 CFR Part 11 Compliance |
Software Validation Package, IQ/OQ Documentation, Physical Validation Test Plate |
IQ/OQ Protocols, SoftMax Pro GxP Compliance Software, SpectraTest LM1 Validation Plate |
Robotic compatible | ● | |||||